ASUS RTX 3090 Liquid Damage Repair — Restoring Power and Control Circuits
This ASUS RTX 3090 liquid damage repair case study documents the diagnosis, extensive component-level repair and post-repair testing of a graphics card suffering from crashes and loss of display.
CASE STUDY: Multi-Circuit Restoration Following Liquid Damage on an ASUS RTX 3090
Repair Specialist: AKM Repairs Ltd, UK
Hardware: ASUS GeForce RTX 3090
Architecture: NVIDIA Ampere
Reported Fault: Crashes and blank screens within minutes of operation, particularly under load
Outcome: Affected power phases and control circuitry restored, followed by thermal monitoring and GPU stress testing
1. Summary
An ASUS RTX 3090 arrived at our workshop after the customer reported crashes and blank screens shortly after startup or when the card was placed under load. Although the GPU could initially power on, it could not maintain normal operation.
Inspection identified liquid damage affecting multiple areas of the power-delivery and control circuitry. The repair required coordinated work across several circuits, including replacement of controllers, voltage regulators, a power stage and damaged resistors.
Through component-level repair, AKM Repairs restored the affected circuitry and retained the existing board. Thermal servicing and post-repair testing completed the process.
For organisations assessing faulty GPU assets, this case illustrates why initial startup alone is insufficient to establish hardware condition—and why the extent of liquid damage must be determined through electrical investigation.
2. Diagnostic Process & Findings
The assessment combined visual inspection, electrical measurements, thermal imaging and software diagnostics to investigate the reported instability.
Corrosion and Contamination:
Visible evidence of liquid damage was present around board components. Inspection established the areas requiring further electrical assessment.
Power-Regulation Faults:
Electrical diagnostics identified faults affecting all voltage rails. Multiple PWM controllers and voltage regulators required replacement, together with one DrMOS power stage on the MSVDD circuit.
Control-Circuit Damage:
Several resistors had shifted from their intended values, and the affected logic section required rebuilding.
The findings established that the repair needed to address multiple connected fault areas. Removing visible contamination alone would not have resolved the damaged components or restored correct circuit operation.
3. Component-Level Repair & Thermal Servicing
Power-Regulation Restoration:
The repair included replacement of:
-
All PWM controllers.
-
The 5V, 1.8V and PEX voltage regulators.
-
One MSVDD DrMOS power stage.
This work restored the affected power phases and addressed the faults identified during electrical diagnosis.
Control-Circuit Restoration:
Resistors with altered values were replaced, and the damaged logic section was rebuilt to restore the affected control circuitry.
Thermal Interface Servicing:
New thermal pads were fitted, and PTM7950 phase-change material was applied to the GPU thermal interface during reassembly. The card was then prepared for powered testing and thermal assessment.
The scope of work reflected the extent of the damage across the board, with both power regulation and control functions addressed before validation.
4. Post-Repair Testing & Validation
Following the repair, the card underwent GPU testing to assess its operation under load:
-
FurMark: Sustained graphics load testing.
-
3DMark: Benchmark workloads to assess operation under demanding graphics conditions.
-
OCCT: Additional GPU stress and diagnostic testing.
-
Thermal monitoring: Thermal-camera assessment during testing to observe heat distribution and identify abnormal heating.
These checks extended the assessment beyond whether the card could power on, addressing the operating conditions associated with the original complaint.
Videos documenting the work and testing were provided to the customer, offering supporting evidence of the repair process and post-repair operation.
For commercial customers, recorded testing helps support informed decisions about returning repaired hardware to service.
5. Outcome & Customer Handover
AKM Repairs restored the ASUS RTX 3090’s affected power phases and logic circuitry through extensive component-level repair, followed by thermal servicing and GPU testing.
The work recovered the existing board despite faults spanning multiple circuits. Customer handover included video documentation of the repair and testing, providing visibility into the work performed and the card’s subsequent operation.
This case demonstrates the importance of assessing liquid-damaged hardware beyond its visible condition. Corrosion was accompanied by changes in component values and failures across the power-regulation and control sections, requiring a systematic investigation and a clearly defined repair scope.
For hardware resellers, workstation operators and businesses managing GPU assets, this approach supports informed repair-versus-replacement decisions and the recovery of suitable hardware for continued use. The viability of each liquid-damage repair depends on the condition of the individual board and the findings of its assessment.
Experiencing GPU crashes, blank screens or suspected liquid damage? Contact AKM Repairs with the hardware model, symptoms, damage history and quantity involved so we can advise on assessment and repair options at our specialist workshop in Newark, Nottinghamshire.
Explore our AI GPU & Workstation Accelerator Repair, GPU Maintenance and GPU Repair services.
AKM Repairs — Restoring Technology. Redefining Standards.
For more information about our services, please explore our AI GPU & Workstation Accelerator Repair, Maintenance Services and standard GPU Repairs.
Don’t forget to connect with us on X (Twitter) and Facebook for quick updates and customer highlights. For repair demos and detailed insights, watch our latest shorts and videos on our YouTube channel and make sure to subscribe so you never miss what’s new!